Carbon monoxide, gas and smoke sensor MOES S03-CGS-EU-MS
- Regular price
- €30,89
- Sale price
- €30,89
- Regular price
-
- Unit price
- per
Couldn't load pickup availability
Čas dostave
Izdelek bomo predvidoma poslali čez: 5 dni





Sensor MOES S03-CGS-EU-MS
It combines the detection of multiple types of hazards in one device for households where gas appliances or a fireplace are in use.
- Audible and visual warnings help to quickly notice a perceived danger.
- The color display also shows the temperature and humidity in the room.
- A backup battery provides temporary power during a power outage.
- The self-test function makes it easy to check operation.
The MOES S03-CGS-EU-MS carbon monoxide, gas and smoke sensor monitors the presence of CO, flammable gases and smoke in the room. When a danger is detected, it triggers an audible alarm with a volume of at least 85 dB and a visual warning, and the color display also shows the temperature and relative humidity.
The device is powered by an electrical outlet, and in the event of a power outage, it is temporarily powered by a built-in 1000 mAh battery. Adjustable screen brightness, a self-test function and the ability to silence the alarm make everyday use easier.
⚖️ Compare features with other products of your choice

Timely detection of danger
The MOES S03-CGS-EU-MS uses an electrochemical sensor to detect carbon monoxide and a photoelectric sensor to detect smoke. It also monitors flammable gases such as methane and butane. The CO measurement range is 0 to 999 ppm, and the default alarm threshold is 49 ppm. Such combined detection is intended for use in rooms where, for example, gas stoves, water heaters or fireplaces are present.

Color display of danger level
The three-color indicator with green, yellow and red allows quick orientation regarding the displayed level of danger. For CO, green indicates values from 0 to 49 ppm, yellow from 50 to 99 ppm, and red indicates values above 99 ppm. For flammable gases, the levels are below 5% LEL, from 5% to less than 15% LEL, and 15% LEL or more. For smoke, the indicator shows values below 0.15 dB/m, from 0.15 to less than 0.30 dB/m, and 0.30 dB/m or more. LEL stands for the lower explosive limit.

Audible and visual warning
When a dangerous level of controlled substances or smoke is detected, an audible and visual alarm is triggered. The audible signal reaches a volume of at least 85 dB. The alarm can be silenced using the button on the front panel. The flashing frequency of the indicator depends on the detected hazard: for gas it is 1 s, 0.5 s or 0.25 s, for smoke it is 0.5 s.

Temperature and humidity display
The color display shows the temperature and relative humidity in the room in addition to information about the detected danger. The humidity measurement range is from 0% to 95% relative humidity with a deviation of ±5% in non-condensing conditions.

Easy management and adjustments
The buttons on the device provide access to the main functions. The central button turns on the sensor and starts a self-test, while separate buttons allow you to adjust the screen brightness and silence the alarm. The sensitivity of the combustible gas detection can also be set: S1 indicates lower sensitivity for methane, and S2 indicates higher sensitivity for butane, alcohol and other combustible gases.

Mains power and battery backup
The sensor is powered by a 100-240 V AC mains supply, 50/60 Hz. The built-in 1000 mAh rechargeable battery provides temporary power in the event of a power outage.

Compact design
The housing made of fire-resistant ABS plastic measures 125.5 × 60.5 × 36.3 mm without plug. The replaceable plug allows the power connector to be replaced without tools. The device is designed to operate at temperatures from −10 °C to 50 °C.

Package contents
- Sensor MOES S03-CGS-EU-MS: 1 pc
- User manual: 1 piece
- Plug: 1 piece
- Packaging safety insert: 1 piece
| Manufacturer | MOES |
|---|---|
| Model | S03-CGS-EU-MS |
| Carbon monoxide detection technology | Electrochemical |
| Smoke sensor type | Photoelectric |
| CO measuring range | 0–999 ppm (±10%) |
| Default CO alarm threshold | 49 ppm |
| CO concentration display | Green: 0-49 ppm; Yellow: 50-99 ppm; Red: above 99 ppm |
| Flammable gas detection levels | GAS Lv1–Lv3 (Lv3: ≥15% LEL) |
| Flammable gas alarm threshold | GAS Lv2 (≥5% LEL) |
| Display of flammable gas concentration | Green: below 5% LEL; yellow: from 5% to less than 15% LEL; red: ≥15% LEL |
| Smoke alarm threshold | ≥0.15 dB/m |
| Smoke level display | Green: below 0.15 dB/m; yellow: from 0.15 to less than 0.30 dB/m; red: ≥0.30 dB/m |
| Setting the gas detection sensitivity | S1: lower sensitivity to methane; S2: higher sensitivity to butane, alcohol and other flammable gases |
| Humidity measurement range | 0-95% relative humidity (±5%, non-condensing) |
| Temperature display | Yes |
| Alarm signaling | Audio and visual |
| Alarm volume | ≥85dB |
| Danger level indication | Three-stage: green, yellow and red |
| Gas indicator flashing frequency | Green: 1 s; yellow: 0.5 s; red: 0.25 s |
| Smoke indicator flashing frequency | 0.5 seconds |
| Alarm silence function | Yes |
| Self-test function | Yes |
| Adjusting the screen brightness | Yes |
| Mains power supply | 100-240V, 50/60Hz |
| Backup battery | Built-in rechargeable battery, 1000 mAh |
| Replaceable plug | Yes |
| Housing material | Fireproof ABS plastic |
| Operating temperature | from −10 °C to 50 °C |
| Dimensions | 125.5 × 60.5 × 36.3 mm (without plug) |
It is important to know
When choosing, it is crucial that you find the right combination of multiple detection types in one device. However, keep in mind that the sensor is powered from a socket, and the backup battery only provides temporary operation in the event of a power outage; the duration of this operation is not specified.
- Combining CO, combustible gas, and smoke detection is useful if you want to monitor multiple detection types with a single device, rather than choosing just one type of sensor.
- The backup battery is not described as a permanent replacement for mains power, so it is worth considering that the duration of operation in the event of a power outage is not specified.
Source of editorial recommendations: general verifiable guidelines for product selection.
In practice
🏠 When you want to combine multiple types of detection
🟢 Very suitable – the device detects CO, flammable gases and smoke, so it makes sense when you want to cover all three types of detection with a sensor.
Answers to frequently asked questions
How long does the sensor work during a power outage?
The built-in battery provides temporary operation in the event of a power outage. The duration is not specified, so it cannot be relied upon as a specific period of time.
Description updated: November 2026
Why buy from ENAA?
- The descriptions on ENAA are designed neutrally, with clear summaries of benefits and functionality, leaving the decision up to the buyer.