{"product_id":"meltem-simplair-ec-s-u-flush-mounted-housing-for-fan-cartridge-side-outlet","title":"Meltem SimplAir-EC S-U flush-mounted housing for fan cartridge, side outlet","description":"\u003cdiv style=\"font-size:1.1em;\"\u003e\n\u003ch2\u003eMeltem SimplAir-EC SU\u003c\/h2\u003e\n\u003cp\u003e The flush-mounted housing for the fan insert is intended for installation solutions in which the exhaust is routed to the side.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e For flush-mounted installation of a fan insert.\u003c\/li\u003e\n\u003cli\u003e The side exhaust allows for lateral direction of the exhaust air.\u003c\/li\u003e\n\u003cli\u003e The housing is intended for use with a separate fan cartridge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003eThe Meltem SU flush-mounted housing has a plastic exhaust port on the side and is without a fire jacket. It includes a housing, end plate, non-return flap and exhaust port and is intended for the installation of the SimplAir-EC fan insert and suction set. The housing has a small installation depth, and the exhaust port can be redirected from the side to the rear exhaust without tools. The automatic plastic non-return flap also acts as a barrier against cold smoke. The break-off points for connecting another room or a toilet connection are already prepared in the housing. The housing is fixed via three screw connections or via the side mounting grooves with the MB-V universal mounting bracket or in a pre-wall installation. A protective cover is included to close the housing during construction.\u003ch3\u003e Usage\u003c\/h3\u003e For use in accordance with DIN 18017-3, for installation in bathrooms, toilets and storage rooms in apartments. The housing may be used in buildings without fire protection requirements or in conjunction with ceiling fire partitions. In buildings with fire protection requirements, it may only be installed outside fire-resistant shafts or air ducts, if a height offset of at least 230 mm is ensured inside the shaft or duct. Fan insert not included.\u003ch3\u003e Technical features:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e Manufacturer: Meltem\u003c\/li\u003e\n\u003cli\u003e Type: SU\u003c\/li\u003e\n\u003cli\u003e Manufacturer's item number: 300507\u003c\/li\u003e\n\u003cli\u003e Installation location: wall \/ ceiling\u003c\/li\u003e\n\u003cli\u003e Installation method: flush-mounted\u003c\/li\u003e\n\u003cli\u003e Blow-out direction: side \/ rear\u003c\/li\u003e\n\u003cli\u003e Connection diameter: 75 mm \/ 80 mm\u003c\/li\u003e\n\u003cli\u003e Second compartment connection on the housing: left \/ bottom \/ right\u003c\/li\u003e\n\u003cli\u003e Cable entry (via membrane gland): bottom right\u003c\/li\u003e\n\u003cli\u003e Housing material: PS\u003c\/li\u003e\n\u003cli\u003e Installation dimensions (W × H × D): 233 × 233 × 104 mm\u003c\/li\u003e\n\u003cli\u003e Weight: 0.55 kg\u003c\/li\u003e\n\u003cli\u003e General building permit: Z-51.1-516\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e Package contents:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e SU flush-mounted housing with end plate, non-return flap and blow-off nozzle\u003c\/li\u003e\n\u003cli\u003e Protective cover during construction\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cbr\u003e\u003ch2\u003eIt is important to know\u003c\/h2\u003e\u003cp\u003e With this product, it is crucial to choose the right housing for your ventilation system, not just for the desired exhaust direction. Before purchasing, check whether you already have the appropriate fan cartridge.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e The housing is not a stand-alone fan; the fan cartridge is purchased separately. It is intended for the SimplAir-EC cartridge, so check if this part is already included in your design.\u003c\/li\u003e\n\u003cli\u003e If you want to connect another room, the connection is already prepared in the housing. This is useful to consider when planning the ventilation of several rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e In practice\u003c\/h2\u003e\u003ch3\u003e 🌬️ Concealed installation with side exhaust\u003c\/h3\u003e\u003cp\u003e 🟢 Very convenient – the housing is designed for flush-mounting, and the air can be directed to the side. It makes sense when you want to include this solution in your room ventilation plan.\u003c\/p\u003e\u003ch2\u003e Answers to frequently asked questions\u003c\/h2\u003e\u003ch3\u003e Can I redirect the exhaust from the side to the rear?\u003c\/h3\u003e\u003cp\u003e Yes. The blow-off nozzle can be repositioned without tools.\u003c\/p\u003e\u003cscript type=\"application\/ld+json\"\u003e\u003cbr \/\u003e\n{\u003cbr \/\u003e\n  \"@context\": \"https:\/\/schema.org\",\u003cbr \/\u003e\n  \"@type\": \"FAQPage\",\u003cbr \/\u003e\n  \"mainEntity\": [\u003cbr \/\u003e\n    {\u003cbr \/\u003e\n      \"@type\": \"Question\",\u003cbr \/\u003e\n      \"name\": \"Ali lahko izpih preusmerim s stranskega na zadnjega?\",\u003cbr \/\u003e\n      \"acceptedAnswer\": {\u003cbr \/\u003e\n        \"@type\": \"Answer\",\u003cbr \/\u003e\n        \"text\": \"Da. Izpihovalni nastavek lahko preusmerite brez orodja.\"\u003cbr \/\u003e\n      }\u003cbr \/\u003e\n    }\u003cbr \/\u003e\n  ]\u003cbr \/\u003e\n}\u003cbr \/\u003e\n\u003c\/script\u003e\u003cp style=\"font-size: 0.9em; color: #666;\"\u003eDescription updated: November 2026\u003c\/p\u003e\u003ch2\u003e Why buy from ENAA?\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e The descriptions on ENAA are designed neutrally, with clear summaries so you can make an informed purchasing decision.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Meltem","offers":[{"title":"Default Title","offer_id":59472360898891,"sku":null,"price":109.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/3457\/3643\/files\/meltem_simplair_ec_s_u_podometno_ohisje_za_ventilatorski_vlozek_stranski_izpih_9410152.jpg?v=1795646984","url":"https:\/\/enaa.eu\/products\/meltem-simplair-ec-s-u-flush-mounted-housing-for-fan-cartridge-side-outlet","provider":"Enaa","version":"1.0","type":"link"}